§ 231-16. Exterior structure.  


Latest version.
  • A. 
    General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare.
    B. 
    Protective treatment. All exterior surfaces, including, but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. All siding and masonry joints as well as those between the building envelope and the perimeter of windows, doors and skylights shall be maintained weather-resistant and watertight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such corrosion, and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement.
    C. 
    Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches (102 mm) high with a minimum stroke width of 0.5 inch (12.7 mm).
    D. 
    Structural members. All structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads.
    E. 
    Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests.
    F. 
    Exterior walls. All exterior walls shall be free from holes, breaks and loose or rotting materials, and maintained weatherproof and properly surface-coated where required to prevent deterioration.
    G. 
    Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance.
    H. 
    Decorative features. All cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition.
    I. 
    Overhang extensions. All overhang extensions, including, but not limited to, canopies, marquees, signs, metal awnings, fire escapes, standpipes and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
    J. 
    Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads.
    K. 
    Chimneys and towers. All chimneys, cooling towers, smokestacks, and similar appurtenances shall be maintained structurally safe and sound and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
    L. 
    Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.
    M. 
    Window, skylight and door frames. Every window, skylight, door and frame shall be kept in sound condition, good repair and weathertight.
    (1) 
    Glazing. All glazing materials shall be maintained free from cracks and holes.
    (2) 
    Openable windows. Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware.
    N. 
    Insect screens.
    (1) 
    During the period from June 1 to August 31, every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored shall be supplied with approved tightly fitting screens of not less than 16 mesh per inch (16 mesh per 25 mm) and every swinging door shall have a self-closing device in good working condition.
    (2) 
    Exception. Screens shall not be required where other approved means, such as air curtains or insect-repellent fans, are employed.
    O. 
    Doors. All exterior doors, door assemblies and hardware shall be maintained in good condition. Locks at all entrances to dwellings units, rooming units and guest rooms shall tightly secure the door. Locks on means-of-egress doors shall be in accordance with this chapter.
    P. 
    Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water.
    Q. 
    Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents.
    R. 
    Building security. Doors, windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within.
    S. 
    Doors. Doors providing access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let shall be equipped with a dead-bolt lock meeting specifications set forth herein. Such dead-bolt locks shall be operated only by the turning of a knob or a key and shall have a lock throw of not less than one inch. For the purpose of this section, a sliding bolt shall not be considered an acceptable dead-bolt lock. Such dead-bolt locks shall be installed according to manufacturer's specifications and maintained in good working order. All dead-bolt locks required by this section shall be designed and installed in such a manner so as to be operable inside of the dwelling unit, rooming unit, or housekeeping unit without the use of a key, tool, combination thereof or any special knowledge or effort.
    T. 
    Windows. Operable windows, located in whole or in part within six feet (1828 mm) above ground level or a walking surface below, that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased or let, shall be equipped with window-sash-locking devices.
    U. 
    Basement hatchways. Basement hatchways that provide access to a dwelling unit, rooming or housekeeping unit that is rented, leased or let shall be equipped with devices that secure the units from unauthorized entry.